Publiora

Menghubungkan ke Publiora...

Publiora

Comparison of interleukin-6 and serum creatinine levels in preeclampsia and normal pregnancy patients: A cross-sectional study in Indonesia

Syerli R. DewiDepartment of Obstetrics and Gynecology, Faculty of Medicine, Universitas Syiah Kuala, Banda Aceh, IndonesiaCut M. YeniDepartment of Obstetrics and Gynecology, Dr. Zainoel Abidin Hospital, Banda Aceh, IndonesiaMunizar MunizarDepartment of Obstetrics and Gynecology, Dr. Zainoel Abidin Hospital, Banda Aceh, IndonesiaTgk. Puspa DewiDepartment of Obstetrics and Gynecology, Dr. Zainoel Abidin Hospital, Banda Aceh, IndonesiaNiken A. UtamiDepartment of Obstetrics and Gynecology, Dr. Zainoel Abidin Hospital, Banda Aceh, IndonesiaRusnaidi RusnaidiDepartment of Obstetrics and Gynecology, Dr. Zainoel Abidin Hospital, Banda Aceh, Indonesia
Narra J (Sinta 1)Vol. 6 No. 1 (2026)10 Februari 2026hal. e3016-e3016
DOI10.52225/narra.v6i1.3016

Abstrak

Preeclampsia (PE) is a complication of pregnancy with high morbidity and mortality, characterized by endothelial dysfunction, systemic inflammation, and impaired renal function. Interleukin-6 (IL-6) and serum creatinine have potential as biomarkers for early detection of PE; however, data from Indonesia are limited. The aim of this study was to compare IL-6 and serum creatinine levels between pregnant women with PE and normotensive controls, as well as their diagnostic performance in identifying PE. A cross-sectional study involving pregnant women with PE and normotensive controls was conducted at Dr. Zainoel Abidin Hospital, Banda Aceh, Indonesia. Serum IL-6 and creatinine levels were measured using the ECLIA method. Levels were compared using the Mann–Whitney test; diagnostic performance was assessed using receiver operating characteristic (ROC) curve analysis, and multivariable logistic regression was used to evaluate combined diagnostic contribution. A total of 68 pregnant women were included, comprising 34 patients with PE and 34 normotensive controls. Median IL-6 levels were significantly higher in the PE group (16.05 pg/mL) than in the control group (3.71 pg/mL). Receiver operating characteristic analysis demonstrated excellent diagnostic performance of IL-6, with an are under the curve (AUC) of 0.831 (95%CI: 0.734–0.929). At an optimal cutoff value of 5.52 pg/mL, IL-6 achieved a sensitivity of 73.53%, specificity of 76.47%, and diagnostic accuracy of 86.76%. Median serum creatinine levels were also significantly elevated in the PE group (0.56 mg/dL) compared with controls (0.44 mg/dL; p<0.001). The AUC for serum creatinine was 0.806 (95%CI: 0.700–0.912), indicating good diagnostic performance. At a cutoff value of 0.475 mg/dL, serum creatinine demonstrated a sensitivity of 70.59%, specificity of 73.53%, and accuracy of 72.06%. Multivariable logistic regression confirmed that IL-6 (B=0.123; p=0.005) and serum creatinine (B=9.306; p=0.023) were independently associated with PE, explaining 57.5% of PE variability (Nagelkerke R²=0.575). These findings indicate that serum IL-6 and creatinine are significantly associated with PE, and their combined assessment shows potential as a predictive biomarker with good diagnostic performance.

Kata Kunci

Preeclampsiabiomarkerinterleukin-6serum creatininediagnostic performancePreeclampsiabiomarkerinterleukin-6serum creatininediagnostic performance

Cari jurnal yang tepat untuk naskah Anda

MatchMind AI mencocokkan abstrak naskah Anda dengan ribuan jurnal terakreditasi dan menampilkan rekomendasi terbaik beserta alasannya.

Coba MatchMind

Lihat profil lengkap jurnal ini

Waktu review, biaya APC, statistik sitasi, indeksasi Scopus, dan banyak lagi.

Buka Narra J

Artikel ini juga tersedia di situs resmi jurnal.

Comparison of interleukin-6 and serum creatinine levels in preeclampsia and normal pregnancy patients: A cross-sectional study in Indonesia | Narra J | Publiora