Publiora

Menghubungkan ke Publiora...

Publiora

Low-cost portable potentiostat for real-time insulin concentration estimation based on electrochemical sensors

Dewi, Fitria YunitaAliwarga, Harry KusumaHandoko, Djati
International Journal of Electrical and Computer Engineering (IJECE) (Sinta 1)Vol. 0 No. 01 Agustus 2025
DOI10.11591/ijece.v15i4.pp3683-3695

Abstrak

Administering incorrect insulin dosages to diabetic patients can be fatal, leading to severe health consequences. Insulin detection, in conjunction with blood glucose monitoring, can significantly enhance diagnostic accuracy. Electrochemical methods for insulin detection offer a low-cost and portable solution. This study presents an insulin concentration estimation system using a customized electrochemical potentiostat operating in real-time via Bluetooth low energy (BLE). Conventional electrochemical sensing, which relies on calibration curves to determine concentration, poses accuracy limitations in portable devices. To address this, we implement a multiple- predictor approach that incorporates peak currents from multiple cycles of cyclic voltammetry responses and the electroactive surface area of a multi- walled carbon nanotube (MWCNT-COOH) modified screen-printed sensor. This modified sensor enhances sensitivity compared to bare screen-printed carbon sensors, making it suitable for low-volume and portable applications. Through cross-validation, our method demonstrated strong performance, achieving a determination coefficient (R²) greater than 0.90 for all training dataset combinations and greater than 0.85 for all testing dataset combinations. Hypothesis testing further confirmed the statistical significance of the electroactive surface area (p=0.006) as predictor, indicating its meaningful contribution to concentration estimation. This approach improves portable detection performance, supporting the development of affordable and reliable personal insulin monitoring systems.

Kata Kunci

Electronics, InstrumentationElectrochemistryCyclic voltammetryElectroactive surface areaInsulin detectionMultiple predictorsPortable potentiostatReal-time detection

Cari jurnal yang tepat untuk naskah Anda

MatchMind AI mencocokkan abstrak naskah Anda dengan ribuan jurnal terakreditasi dan menampilkan rekomendasi terbaik beserta alasannya.

Coba MatchMind

Lihat profil lengkap jurnal ini

Waktu review, biaya APC, statistik sitasi, indeksasi Scopus, dan banyak lagi.

Buka International Journal of Electrical and Computer Engineering (IJECE)

Artikel ini juga tersedia di situs resmi jurnal.

Low-cost portable potentiostat for real-time insulin concentration estimation based on electrochemical sensors | International Journal of Electrical and Computer Engineering (IJECE) | Publiora