Effect of Coating of Earthed Enclosure and Multi-Contaminating Particles on Breakdown Voltage inside Gas Insulated Bus Duct

Abd Allah, Mousa Awad AllahWard, Sayed Abo El SouadEZZ-El Din, Amr Ameen
International Journal of Electrical and Computer Engineering (IJECE) (Sinta 1)Vol. 0 No. 01 Agustus 2014

Abstrak

Metallic particle contamination is one of the areas of insulation design that are considered critical. This paper demonstrates the control of metallic particles in gas insulated bus duct (GIBD) by using dielectric coating on the inside surface of the outer enclosure of a coaxial electrode system. Several models of GIBD with single and multi-contaminating particles will be studied. In this paper, the Finite Elements Method (FEM) is used to evaluate the electric field distribution on and around single and multi-contaminating wire particles which in contact with dielectric coating of earthed enclosure inside GIBD. The effect of changing the length and the radius of middle particle for multi-contaminating particles on the electric field values are studied. Breakdown Voltage calculations for gas mixtures with single and multi-contaminating wire particles are studied. The effects of gas pressure on the breakdown voltage for various fractional concentrations of SF6-gas mixtures with and without particle contamination and also with and without coating of earthed enclosure are studied. The optimum gas mixture which gives higher dielectric strength with lower cost is also determined. The effect of coating thickness of earthed enclosure on the breakdown voltage for various fractional concentrations of SF6-gas mixtures is also studied. Finally, the effect of length and hemi-spherical radius of multi-contaminating particles on the breakdown voltage with various SF6-gas mixtures and varying gas pressure one time and another time with fixed pressure are studied.DOI:http://dx.doi.org/10.11591/ijece.v4i4.5693

Kata Kunci

Electrical (Power)CoatingMulti-ParticlesElectric FieldBreakdown VoltageGas Mixtures

Cari jurnal yang tepat untuk naskah Anda

MatchMind AI mencocokkan abstrak naskah Anda dengan ribuan jurnal terakreditasi dan menampilkan rekomendasi terbaik beserta alasannya.

Coba MatchMind

Lihat profil lengkap jurnal ini

Waktu review, biaya APC, statistik sitasi, indeksasi Scopus, dan banyak lagi.

Buka International Journal of Electrical and Computer Engineering (IJECE)

Artikel ini juga tersedia di situs resmi jurnal.

Effect of Coating of Earthed Enclosure and Multi-Contaminating Particles on Breakdown Voltage inside Gas Insulated Bus Duct | International Journal of Electrical and Computer Engineering (IJECE) | Publiora